BWYYR - 040906 APPLICATION SOLUTION IPPM FLUORIDE/ (SUP DAT)

  • MSDS: BWYYR
  • Manufacturer: ORION RESEARCH INC
  • Product Name: 040906 APPLICATION SOLUTION IPPM FLUORIDE/ (SUP DAT)
  • National Stock Number: 6630-00N057882
Product Identification

Product ID:040906 APPLICATION SOLUTION IPPM FLUORIDE/ (SUP DAT)
MSDS Date:04/06/1988
FSC:6630
NIIN:00N057882
MSDS Number: BWYYR

Responsible Party
ORION RESEARCH INC
529 MAIN ST, SHRAFFT CENTER
BOSTON, MA 02129
US

Emergency Phone: 617-242-3900

Info Phone: 617-242-3900

Preparer: THOMAS F FLYNN

Cage: 30260

Contractor
ORION RESEARCH INC
BOSTON, MA 02129 US

Telephone: 617-242-3900

Cage: 30260

Ingredients

SODIUM FLUORIDE (CERCLA)

CAS: 7681-49-4

RTECS: WB0350000

Fraction By Weight: <0.01%

OSHA PEL NONE.

ACGIH TLV: NONE.

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ACETIC ACID (CERCLA)

CAS: 64-19-7

RTECS: AF1225000

Fraction By Weight: 0.7%

OSHA PEL 10 PPM

ACGIH TLV: 10 PPM/15 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


(CYCLOHEXYLENEDINITRILO)TETRA-ACETIC ACID; (CDTA)

CAS: 25637-70-1

Fraction By Weight: 0.2%

OSHA PEL N/K

ACGIH TLV: N/K


DYE; (DYE COLORING)

Fraction By Weight: <0.1%

OSHA PEL N/K

ACGIH TLV: N/K


WATER; (DE-IONIZED WATER AND NEUTRAL SALTS)

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: <99.0%

OSHA PEL N/K

ACGIH TLV: N/K


NEUTRAL SALTS

Fraction By Weight: <99%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGESTION MAY CAUSE NAUSEA,
BREATHING DIFFICULTIES, AND DAMAGE TO STOMACH AND DIGESTIVE TRACT.
LOW HAZARD FOR SKIN AND INHALATION. CHRONIC: NONE SPECIFIED BY
MANUFACTURER.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:IRRITATION OF RESPIRATORY TRACT, UPSET STOMACH
OR NAUSEA, IRRITATION OF EYES, NOSE, THROAT.
Medical Cond Aggravated by Exposure:RESPIRATORY ALIMENTS, PERSONS WITH
SENSITIVE SKIN MAY BE AFFECTED.

First Aid

First Aid:EYES: IRRIGATE WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES.
INGEST: DILUTE WITH LARGE AMOUNTS OF WATER. DO NOT INDUCE VOMITING.
CONSULT A PHYSICIAN. SKIN: IRRIGATE WITH PLENTY OF WATER.

Fire Fighting

Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, ALCOHOL FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:EMITS TOXIC FUMES IF HEATED TO
DECOMPOSITION.

Accidental Release

Spill Release Procedures:VACUUM UP AND WASH DOWN DRAIN WITH LARGE
AMOUNTS OF WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP AWAY FROM OXIDIZERS AND CAUSTICS.
KEEP WELL SEALED AND STORE AT ROOM TEMPERATURE.
Other Precautions:ALWAYS WASH HANDS THOROUGHLY WITH SOAP AND WATER
AFTER WORKING WITH THIS MATERIAL.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN.
Ventilation:LOCAL EXHAUST.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS.
Other Protective Equipment:LAB COAT. EMERGENCY EYE WASH SHOULD BE
AVAILABLE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
TRADE NAME/PART NO: TISAB STANDARD. % VOLAT: 3.8 (WT).

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Spec Gravity:1.02 (H*2O=1)
pH:5-5.5
Solubility in Water:MISCIBLE.
Appearance and Odor:GREEN LIQUID, VINEGAR LIKE ODOR.
Percent Volatiles by Volume:SUPDAT

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS (HNO*3, CHROMIC ACID SODIUM PEROXIDE); CONTACT WITH
STRONG CAUSTICS CAN CAUSE SPATTERING.
Stability Condition to Avoid:HEAT AND FLAME.
Hazardous Decomposition Products:TOXIC GASES SUCH AS CARBON MONOXIDE
MAY BE RELEASED DURING A FIRE.

Disposal

Waste Disposal Methods:DILUTE NEUTRALIZED SOLUTION DOWN DRAIN WITH
EXCESS WATER; OBSERVE ALL LOCAL, STATE & FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.